Kuso Relock® Calculation Formula
M = 0.17*F*d
M = tightening torque on the adjusting nut (Nmm)
F = axial force of the adjusting nut (N)
d = nominal diameter of the adjusting nut (mm)
where the axial force F must not exceed the following maximum value:
F <255*m*d
m = thread length (mm)